HVAC Balance Report Form Template
Streamline Your HVAC Testing and Balancing Process
Are you tired of dealing with messy reports and unclear documentation for your HVAC projects? The HVAC Balance Report Form Template is designed to help HVAC professionals like you create clear, organized, and comprehensive air balancing reports. This template simplifies the documenting process, enhancing accuracy in testing and balancing, improving communication with clients, ensuring compliance with industry standards, and saving you valuable time. Experience a hassle-free way to manage your HVAC balance reports with our easy-to-use live template.
When to use this form
Use this form whenever you need to verify and document airflow and pressures after an install, retrofit, or major service. Field techs, TAB contractors, commissioning agents, and facility managers benefit from a clear snapshot of design vs. actual data by zone. Run it during seasonal changeover, when occupants report hot or cold rooms, or before handover to reduce punch-list items. Pair this with the HVAC Commissioning checklist form to confirm equipment start-up and control sequences before balancing. After corrective work, keep performance steady with the HVAC Maintenance checklist form. The result is a reliable air balancing report that supports comfort, code compliance, and energy savings, with traceable readings, adjustments, and sign-offs.
Must Ask HVAC Balance Report Questions
- What is the design airflow (CFM) and the measured airflow for each zone or terminal?
This side-by-side check confirms whether each space meets design intent or needs damper or fan adjustments. It improves accuracy and provides proof in your test and balance report.
- What are the fan setpoints and the measured total/static pressure at the test ports?
Linking setpoints to measured pressure reveals duct restrictions, dirty filters, or control tuning issues early. It helps stabilize airflow across operating modes and reduces callbacks.
- For each VAV terminal, what are the cooling/heating setpoints, damper position, and minimum airflow?
These details verify ventilation rates and comfort in both occupied and unoccupied states. They also expose sensor or actuator faults that can skew readings.
- What are the target and actual room temperature, relative humidity, and pressure differential?
Comparing targets to actuals confirms comfort and pressurization, which is critical for labs, clinics, and kitchens. It helps you document risk and prioritize fixes by area.
- What issues were found and what corrective actions were taken or recommended, with dates and responsible party?
This turns findings into a clear plan and accountability trail. You can schedule follow-ups using the Preventive maintenance checklist form to ensure issues stay resolved.